Bionaire BAP1500 Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
With proper care and use, this Bionaire
®
air purifier will give you fresh, clean air
for many years.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
DESCRIPTIONS (SEE FIG.1)
A.Power Light
B.Speed Control
C.Oscillation Button
D.Ioniser Control
E.Filter Indicator Light
F. Ioniser Light
G.Washable Foam Pre-filter
H.Inlet Grill
I. PERMAtech™ Filters (2 pcs)
J. Filtered Air Outlet
SAFETY PRECAUTION
Carefully read and retain all instructions before
using the air purifier.
•To avoid fire or shock hazard, check that the
voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.
Keep cord out of heavy traffic areas and to
avoid fire hazard, never put the cord under
rugs, or near any heat source.
Carefully discard any plastic wrapping that
was used for the packaging. If the filter is
covered by a bag when shipped, remove
plastic bag before use.
Do not use the air purifier outside.
Do not place the unit near any heat source or
in direct sunlight.
Always unplug the air purifier before moving it,
opening the grill, changing the filters, cleaning
the air purifier or whenever it is not in use.
Do not use in or around water or any other
liquids. Do not attempt to wash the unit under
running water.
Use appliance only for intended household
use as described in this manual.
Ensure that all air openings are not restricted
or covered in any way.
Do not place anything on top of the unit.
Never insert any object into any openings.
Do not use the air purifier if any part is
missing or damaged in any way.
Do not attempt to repair or adjust any
mechanical functions of this unit. If the unit
becomes damaged return to the place of
purchase or phone the helpline number on
the back of this leaflet.
If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
agent or a similarly qualified person in order
to avoid hazard.
The air purifier contains no user serviceable
parts and should the product suffer damage
or breakdown it must be returned to the
manufacturer or its service agent.
Should the air purifier stop working, first check the
fuse in the plug (UK only) or fuse/circuit breaker at
the distribution board is operating, before
contacting the manufacturer or service agent.
The ioniser may cause a static charge to build up
on the air output grill. A static charge may be felt if
the unit is not properly grounded. To avoid a static
charge, plug the unit into a grounded outlet, or
properly install a ground adaptor. The static shock
will not occur if the ioniser is off.
Close supervision is necessary when any
appliance is used by or near children, or
disabled persons.
HOW THE AIR PURIFIER WORKS
Dirty, dust laden air is drawn through the back of
the air purifier and through the multi-stage
filtration system.
1. The carbon filter will help clear odours making
the air cleaner and fresher.
2. The PERMAtech™ filter entraps 99% of all
smaller visible and non-visible particles down
to 2 microns in size.
IONISER
Your Bionaire
®
Air Purifier has an independently
controlled ioniser, which when turned on,
releases negative ions into the outgoing filtered
air. Ions are tiny particles that carry either a
positive or negative charge. These ions exist
naturally all around us in the air, water and
ground. Both positive and negative ions are
colourless, odourless and completely harmless.
Negative ions help the air purification process
by attaching themselves to very small airborne
particles in the room. These particles take on a
negative charge and may join with positively
charged particles, such as dust, pollen, smoke
and pet dander to form larger particles that are
then more readily captured by the filter system,
or they may be attracted to positively charged
surfaces like walls or floors.
You may also note, after extended use, that dust
may have collected around the grills or front panel.
This is from the ionisation effect caused by the
negative ions exiting from the air outlet.This dust
does not come from the air output, but Is drawn out
U.K. and IRELAND
of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be easily
removed with a clean, dampened cloth or soft brush.
NOTE: it is important to clean the PERMAtech™
filters at recommended intervals. Using the ioniser
in conjunction with dirty filters may result in dirty
particles exiting the air purifier and being attracted
to walls, carpets, furniture and other household
objects. These dirty particles may prove very
difficult to remove.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove
the plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (rear grill) or
filtered air outlet.
3. Remove the inlet grill by pulling the grill
towards you.
4. Remove both PERMAtech™ filters by gripping
on both sides and pulling forward.
5. Remove protective plastic bag from each filter
cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see
Fig. 2). The filter clip should easily slide onto
the filter hang tabs. Do not use force whilst
attaching the filter clip to the filter. Align the
clip on the PERMAtech™ filter with the rails
on the inside of the unit.(see Fig. 3)
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into
position (the grill only goes on one way).
NOTE: Do not point outlet towards wall.
OPERATING INSTRUCTIONS
Your remote control requires (2) AAA batteries
(not included) for operation. Remove batteries
before discarding the remote control. To install
the batteries, simply depress and slide the back
of the remote control with your thumb on the
arrow indentation. Insert batteries according to
the diagram shown inside and replace cover.
DO NOT mix old and new batteries.
DO NOT mix alkaline, standard (carbon-zinc)
or rechargeable (nickel-cadmium) batteries.
1. Plug into a suitable electrical outlet.
2. Press the power button ( ) on the control
panel or the remote control. The unit will turn on
high only the first time the unit is turned on. All
other times it is turned on, the unit remembers
the last speed selected and will turn on at that
speed and the power light will illuminate letting
you know the power is on.
3. You can then select the desired speed
setting. This air cleaner has three speed
settings. You can select from HIGH ( ),
MEDIUM( ), or LOW ( ) by pushing the
desired operating speed button on the control
panel or the remote control.
4. To release negative ions into the filtered air,
press the ioniser button ( ) either on the
control panel or the remote control and the
light will illuminate.
5. The ioniser will not work unless the unit is
running.
6. For optimum air filtration, it is recommended to
operate the air purifier continuously. Its rugged
motor is designed to give many years of service.
7. For continuous use it is recommended to operate
the air purifier at the Medium ( ) setting. For
quieter operation or use in a bedroom, select the
Low ( ) setting. When high levels of air pollution
are present, select the HI ( ) setting to quickly
circulate clean filtered air.
8. The air purifier is equipped with oscillation. To
start and stop oscillation of the air cleaner,
push the button identified as Oscillation ( )
on the remote control or control panel.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before
cleaning.
2. The outside of the air purifier can be cleaned
with a soft, clean dampened cloth.
3. The rear air inlet grill can be removed and
washed in warm soapy water (not dishwasher
safe). Dry before replacing in the unit.
4. The filtered air outlet can be cleaned of dust
with a small, soft brush.
5. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
PERMATECH
TM
FILTER CLEANING
Filter Indicator Light (E) - Your air purifier has an
indicator light that illuminates when it is time to
clean the PERMAtech™ filters.
1. Every few weeks check the condition of the
pre-filter.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove it
from the inlet of the grill and wash it in warm soapy
water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, check the
condition of your PERMAtech™ filters. If the
filters are dirty, remove them by gripping on
both sides and pulling forward.
4. To clean the PERMAtech™ filter use a crevice
tool or brush attachment with your vacuum
cleaner. Run the attachment along the inlet and
outlet side of the filter trying to clean between the
pleated filter layers. (see Fig. 4).
2 3
BAP1500I05M1 v.qxd 2/19/05 10:15 AM Page 7
Vue de la page 2
1 2 3 4 5 6 7 8 ... 27 28