Bionaire BAP336 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Aspirateurs Bionaire BAP336. Bionaire BAP336 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
EverFresh
TM
Air Exchange
System
MODEL BAP336
Read instructions before operating.
Retain for future reference.
Instruction Leaflet
INFO-LINE
If after having read this leaflet, you have any
questions or comments on air cleaner,
call 1-800-253-2764 in North America.
8. If it is a black washable filter,
clean it as described in step 6.
9. Remove the rubber Vacuum
Plug from opening #5.
See Figure 25.
10. Using a vacuum with a hose
and a crevice tool, GENTLY
vacuum the dust from the core
by accessing openings #2 and
#5. See Figure 26.
CAUTION: Avoid applying
pressure or scraping the surface
of the core with the crevice
tool as this may damage the
core and decrease performance
of the Air Exchange System.
11. Replace the rubber Vacuum
Plug in opening #5. See Figure 25.
12. After the filters are completely dry replace the three black filters
over openings #2, #3, #4.
13. Insert a clean, dry black filter or a new white electrostatic filter
over opening #1.
14. Clean the rear grill with warm soapy water. (Not dish washer
safe). Dry with a soft cloth.
15. Remove dust from the front grill with a small soft brush or cloth.
16. Wipe down the rest of the unit with a clean, damp cloth.
WARNING: DO NOT IMMERSE THE AIR EXCHANGE
SYSTEM IN WATER.
17. Reinstall the rear grill:
See Figure 27.
Put the unit with the front grill
face down on the surface.
Place the grill on the rear of the
unit with the thumb opening
toward the bottom (power
cord side) of the unit.
Gently press down on the
edges of the grill until all edges
are securely latched.
18. Put the unit on the table in the
normal position and replace
the front grill. See Figure 28.
19. Slide the Air Exchange Unit
into the Window Sealing
Frame and push until it locks in
place.
20. Insert the electrical plug into the outlet and turn the unit on.
21. Reset the service indicator by inserting the tip of a paper
clip into the Service Reset Hole (5) and gently pressing the
button inside the hole.
22. The Service Indicator bar graph should reappear.
Replacement Filters
Order these filters by calling 1 (800) 253-2764
Problem Solution
System will not
operate
Decreased airflow
Drafts around
window
Confirm that the unit is plugged into a
working electrical outlet.
Confirm that the Damper Switch (1) is
in the ON position.
Check to make sure the system is on
by pressing the Mode Button (2).
Make sure that all bags have been
removed from the filters.
It should be noted that the air entering
the room is designed to be at a low
flow rate to prevent drafts.
Confirm that nothing is blocking the air
inlet and outlet.
If “SERVICE” is displayed and the per-
formance bars are low, the filters need
to be cleaned. See Routine
Maintenance Instructions.
Check the condition of the filters.
See Routine Maintenance Instructions.
Check to make sure that the foam seal-
ing system is correctly installed.
The leftover foam segments can be
used to seal any remaining openings.
Routine Maintenance
The Bionaire
®
Air Exchange System is easy to use and maintain.
It includes filters that remove dust from air that is circulated through
the system. These filters will need to be cleaned or replaced with
use. The Service Indicator bar graph on the display (6) shows when
service is needed. The Service Indicator bar graph decreases - and
when the bars disappear, the filters need to be cleaned. The aver-
age duration between cleanings is about three months.
WARNING: Do not attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void the warranty. This
unit contains no user serviceable parts. Only qualified personnel
should perform servicing—other than what is described in this manual.
About the Filters
There are three black washable filters
installed in the Air Exchange System.
Each has a single tab that locks
them into the unit. See Figure 18.
There is one two-tab filter installed
in the Air Exchange System. This
will either be a black washable filter
or a white disposable Electrostatic
filter. The Electrostatic filter removes
smaller particles from the circulating
air. See Figure 19.
PERFORMING MAINTENANCE
1. Confirm that the Service Indicator
bars (6) no longer illuminate and
the word "SERVICE" displays. This
signals that maintenance is
required.
2. Turn off and unplug the unit.
3. Remove the Air Exchange System
from the Window Sealing Frame: See
Figure 20.
Grasp each side of the Air
Exchange System and
gently pull it toward you.
Place the unit on a clean,
level surface.
4. Remove the front grill.
See Figure 21.
5. To remove the rear grill:
See Figure 22.
Put the unit with the face
down on the surface.
Place your thumb under
the opening in the rear grill
and pull up. One side of
the grill will lift up and you
will be able to slide the grill
out.
6. Remove the black filters from
openings #2, #3, and #4. Gently
wash these filters with mild soapy
water. Rinse in warm running
water. Shake off excess water
and allow to air dry completely.
See Figure 23.
7. Remove the filter from opening #1.
If it is a white electrostatic filter, dis-
card it and replace with a fresh fil-
ter. Call 1 (800) 253-2764 to order
replacement filters. See Figure 24.
Filter Part
Number
APF18
APF19
APF20
Quantity
Required
1 ea.
3 ea.
1 ea.
Description
Electrostatic Filter, 2-Tab - Optional
Washable Foam Filter 1-Tab
Washable Foam Filter 2-Tab
Service Instructions
If you need to exchange the unit within 30 days of purchase, please
return it in its original carton with the sales receipt to the store from
which it was purchased.
If you need to return the unit beyond 30 days after you purchased
it, review the warranty information provided with the unit and call
1-800-253-2764 for warranty service. You will be given a return
authorization number and instructions returning the unit from the
customer service representative.
WARRANTY
The Manufacturer warrants to the first retail purchaser, for FIVE ( 5 )
YEARS from the date of original purchase, either to repair or replace
at its option, without charge (parts and labor), any supplied or man-
ufactured part of this Air Exchange System which, upon inspection
by an authorized service center, proves to have failed in normal use
due to defects in material or workmanship, or at its option, to
replace the unit. Operation under conditions other than those rec-
ommended or at voltages other than the voltage indicated on the
unit, or any attempts by unauthorized personnel to service the unit
or modify it, will render the guarantee void. The Manufacturer shall
not be liable for any personal injury, property damage or any inci-
dental or consequential damages of any kind (including water dam-
age), resulting from defects, malfunctions, misuse, improper installa-
tion or alteration of the product.
THE MANUFACTURER EXPRESSLY DISCLAIMS ALL
RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR
INCIDENTAL LOSSES CAUSED BY USE OF THIS PRODUCT.
The provisions of this Warranty are in addition to, and not a
modification of, or subtraction from the statutory warranties and
other rights and remedies contained in any applicable legislation
and to the extent that any such provision purports to disclaim,
exclude or limit any such statutory warranties or other rights or
remedies, such provisions shall be deemed to be amended to the
extent necessary to comply therewith.
For Warranty Service, please call 1-800-253-2764 in
North America.
KEEP THIS NUMBER FOR FUTURE REFERENCE.
A Bionaire
®
consumer service representative will help determine
which is the best procedure for your Air Exchange System to be
repaired.
If you have questions or comments, feel free to write us at:
Consumer Service Department
13120 Jurupa Avenue
Fontana, CA 92337
Bionaire
®
, the Bionaire logo
®
and EverFresh
TM
are trademarks of
JCS/THG, LLC.
O
n
O
f
f
Figure 28
Figure 25
Bionaire
®
JCS/THG, LLC
Consumer Service Department
13120 Jurupa Avenue
Fontana, CA 92337
BAP33605EM2/9100040002234 Printed In China
TROUBLESHOOTING
Figure 18
Figure 19
O
n
O
f
f
Figure 21
Figure 23
Opening # 2
Opening # 3
Opening # 5
Opening
# 4
Figure 24
Opening # 1
Figure 20
Figure 22
Figure 26
Figure 27
BAP33605EM2.qxd 10/14/05 9:27 AM Page 1
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Instruction Leaflet

EverFreshTMAir ExchangeSystemMODEL BAP336Read instructions before operating. Retain for future reference.Instruction LeafletINFO-LINE If after having

Page 2

6.Next you must customize the Plastic Extender Panels so thatthe Window Sealing Frame will fit securely in your window. EachPlastic Extender Panel is

Commentaires sur ces manuels

Pas de commentaire